MuxRates

Quantity is how many containers you have. The result is how many tributaries fit, the path, and the leftover line rate. The choices stay in the URL, so you can share them.

Result: standard mapping

How many DS0s are in an OC-12?

An OC-12 carries 8,064 DS0s, per Telcordia GR-253 and ANSI T1.107.

8,064

DS0s in an OC-12

Working

OC-12 → 12 × OC-1 (STS-1) → 28 × DS1 → 24 × DS0

  1. 12 × OC-1 (STS-1) in each OC-12 Telcordia GR-25312 × OC-1 (STS-1). Channelized OC-12 is 12 STS-1s.
  2. 28 × DS1 in each OC-1 (STS-1) Telcordia GR-253Seven VT groups × four VT1.5 (DS1).
  3. 24 × DS0 in each DS1 ANSI T1.10724 payload timeslots. The framing bit adds 8 kbit/s and brings the line rate to 1.544 Mbit/s.

Leftover capacity

105.984 Mbit/s of each OC-12 line rate (622.080 Mbit/s) sits outside 8,064 × 64 kbit/s of DS0 line rate (516.096 Mbit/s). That remainder is overhead, fixed stuff or justification. It is not another whole tributary.

By bit rate only

Dividing the line rates gives 9,720, which floors to 9,720 DS0s by bit rate only. The standard mapping is 8,064. Use the mapping.

Share this result. Pairing page